Skip to main content

Table 2 Sensitivity, specificity, positive and negative predictive values of blood sucrose for diagnosis of GDL in horses after administration of 1 g/kg of sucrose via nasogastric intubation

From: Diagnostic accuracy of blood sucrose as a screening test for equine gastric ulcer syndrome (EGUS) in adult horses

Time of sampling (min)

Cut-off (µmol/l)

Disease present

Disease absent

Sp (%)

Se (%)

NPV (%)

PPV (%)

95% CI

95% CI

95% CI

95% CI

45

5.80

71

31

48.1

50.7

30.0

69.2

30–67

39–63

18–45

55–81

90

6.05

71

31

43.3

66.2

35.1

73.4

26–63

54–77

20–53

61–84

  1. GL gastric lesions, Se sensitivity, Sp specificity, NPV negative predictive value, PPV positive predictive value, 95% CI 95% confidence intervals